Skip to main content

Table 1 Changes of gait spatiotemporal parameters \(\bar x\) in 85 patients before operation and 6 months after operation (± s)

From: The efficacy of 3D gait analysis to evaluate surgical (and rehabilitation) outcome after degenerative lumbar surgery

time

Number

Stride duration (s)

Standing time(s)

Swing time(s)

Single support phase(%)

Dual support phase (%)

Stride length(m)

step size (m)

Pace (m/s)

Cadence (step/min)

Step width (m)

Before surgery

85

1.22 ± 0.13

0.75 ± 0.12

0.47 ± 0.05

38.70 ± 2.25

11.15 ± 3.48

0.99 ± 0.19

0.51 ± 0.15

0.82 ± 0.18

99.18 ± 9.27

0.10 ± 0.07

6-month post-surgery

85

1.09 ± 0.07

0.6 7 ± 0.13

0.42 ± 0.05

38.75 ± 3.02

10.21 ± 1.35

1. 22 ± 0. 1 9

0.6 1 ± 0.27

1.17 ± 0.13

105.83 ± 6.24 _

0.09 ± 0.03

t -value

 

8.118

4.169

6.519

0.122

2.322

7.892

2.985

14.433

5.490

0.784

P value

 

0.000

0.000

0.000

0.903

0.021

0.000

0.003

0.000

0.000

0.434