Skip to main content

The optimal introversion angle and length of pedicle screw to avoid L1-S1 vascular damage

Abstract

Background

posterior pedicle screw fixation is common method, one of the most severe complications is iatrogenic vascular damage, no report investigated association of different introversion angles (INTAs) and length of pedicle screw. The aims were to investigate the optimal introversion angle and length of pedicle screw for improving the safety of the operation, and to analyze the differences of vascular damage types at L1-S1.

Methods

Lumbar CT imaging data from110 patients were analyzed by DICOM software, and all parameters were measured by new Cartesian coordinate system, INTAs (L1-L5:5°,10°,15°,S1: 0°, 5°,10°,15°), DO−AVC (the distance between the origin (O) with anterior vertebral cortex (AVC)), DAVC−PGVs (the distance between AVC and the prevertebral great vessels (PGVs)), DO−PGVs (the distance between the O and PGVs). At different INTAs, DAVC−PGVs were divided into four grades: Grade III: DAVC−PGVs ≤ 3 mm, Grade II: 3 mm < DAVC−PGVs ≤ 5 mm, Grade I: DAVC−PGVs > 5 mm, and N: the not touching PGVs.

Results

The optimal INTA was 5° at L1-L3, the left was 5° and the right was 15° at L4, and screw length was less than 50 mm at L1-L4. At L5, the left optimal INTA was 5° and the right was 10°, and screw length was less than 45 mm. The optimal INTA was 15° at S1, and screw length was less than 50 mm. However, screw length was less than 40 mm when the INTA was 0° or 5° at S1.

Conclusions

At L5-S1, the risk of vascular injury is the highest. INTA and length of the pedicle screw in lumbar operation are closely related. 3 mm interval of screw length may be more preferable to reduce vascular damage.

Peer Review reports

Introduction

Posterior lumbosacral fixation with pedicle screw is common method for treatment various spinal diseases. However, one of the most severe complication of spinal surgery is iatrogenic vascular damage [1,2,3,4]. In spite of the low incidence (less than 1%) of vascular injury during posterior spine surgery, the mortality rate is as high as 61% if the iliac artery and aorta are injured [3, 5]. Computer assist system can improve pedicle screw accuracy, but can’t completely avoid vessel damage [6, 7]. Hence, mastering the optimal introversion angles (INTAs) and insertion depth of pedicle screws can improve the safety of operation. To our knowledge, although a few studies focused on the relationship between INTA and prevertebral great vessels (PGVs) [8, 9], no study investigated association of different INTAs and length of pedicle screw. Therefore, the aims of this study were to investigate the maximum safe distance between pedicle screw entry point and the edge of the blood vessel, and to analyze the relationship of pedicle screw long contacting with PGVs and different INTAs.

Materials and methods

Subjects

Patients of orthopedic inpatient department with lumbar disc herniation (LDH) from January 1, 2019 to December 31, 2021 were included. The inclusion criteria were: age 40 to 80 years, intact lumbosacral CT data from L1-S1.Exclusion criteria: (1) imaging data with unclear. (2) Patients diagnosed with lumbar deformity, lumbar fractures, tumors tuberculosis, spondylolisthesis. (3) Patients with history of retroperitoneal surgery or spinal surgery. Before the study was carried out, the Ethics Committee of the People’s Hospital of China Three Gorges University had approved the research plan. All participants signed an informed consent allowing their clinical data to be used for the research study.

CT image measurement

L1-S1 was scanned by dual-source spiral CT, and then images were imported to PACS workstation. All images were analyzed by DICOM software. The image (the cross-section of each lumbosacral vertebral body) passing through the widest plane of the bilateral pedicles was selected as all parameters’ measurement. The new Cartesian coordinate system developed by Takeshita et al. was used to construct the trajectory of pedicle screw [10], and the following parameters were measured (Figs. 1 and 2):

Fig. 1
figure 1

LAVC−PGV and DO−AVC with different INTAs in L1-S1, SO−AVC= LAVC−PGV+ DO−AVC. AA: abdominal aorta, IVC: inferior vena cava, LCIA: left common iliac artery, RCIA: right common iliac artery, LCIV: left common iliac vein, RCIV: right common iliac vein. LEIA: left external iliac artery, LIIA: left internal iliac artery, REIA: right external iliac artery, RIIA: right internal iliac artery, DAVC−PGV: the distance between AVC and PGV, AVC: anterior vertebral cortex, PGV: prevertebral great vessels, INTA: introversion angles, L: lumbar, S: sacral. At L1-L5 (figure a, b, c), A, B and C represent the left INTA with 5°, 10° and 15°, respectively; A′, B′ and C′ represent the right INTA with 5°, 10° and 15° respectively. At S1 (figure d), A, B, C ,D represent the left INTA at 0°, 5°, 10° and 15°, respectively; A′, B′, C′ and D’ represent the right INTA at 0°, 5°, 10° and 15° respectively

Fig. 2
figure 2

The distance from the needle insertion point to the adjacent blood vessels of the vertebral body from CT images. AA: abdominal aorta, IVC: inferior vena cava, LCIA: left common iliac artery, RCIA: right common iliac artery, LCIV: left common iliac vein, RCIV: right common iliac vein. LEIA: left external iliac artery, LIIA: left internal iliac artery, REIA: right external iliac artery, RIIA: right internal iliac artery, INTA: introversion angles, L: lumbar, S: sacral. At L1-L5 (figure a, b, c), A, B and C represent the left INTA with 5°, 10° and 15°, respectively; A′, B′ and C′ represent the right INTA with 5°, 10° and 15° respectively. At S1 (figure d), A, B, C ,D represent the left INTA at 0°, 5°, 10° and 15°, respectively; A′, B′, C′ and D’ represent the right INTA at 0°, 5°, 10° and 15° respectively

(1) New Cartesian coordinate system: the origin point (O) was defined as the middle of the base of the superior facet, which was the entry point of the pedicle screw. A line connecting the middle points of both bases of the superior facets was defined as the X-axis, the line passing through the O and perpendicular to the X-axis was defined as the Y-axis.

(2) INTA: the angle between the pedicle screw trajectory with Y axis (L1-L5: 5°, 10°, 15°. S1: 0°, 5°, 10°, 15°), it was assumed that pedicle screws pass through the isthmus of pedicle.

(3) DAVC−PGVs: the length between the anterior vertebral cortex (AVC) and the PGVs with different INTAs.

(4) DO−AVC: the distance between the O and the AVC with different INTAs.

(5) DO−PGVs: the distance between the O and the PGVs with different INTAs.

(6) In this study, abdominal aortic injury was mainly considered at L1-L3, arterial and venous injury was considered at L1-S1 (Fig. 1). With different INTAs, the DAVC−PGVs are divided into four grades: DAVC−PGVs ≤ 3 mm was Grade III, 3 mm < DAVC−PGVs ≤ 5 mm was Grade II, DAVC−PGVs > 5 mm was Grade I, and the untouching PGVs was recorded as N. Percentage of each grade = grade number/total number×100%.

Statistical analysis

The statistical analysis was conducted using a standard SPSS 26.0 (SPSS Institute, Chicago, IL) software package. Data were expressed as the mean ± standard deviation. A two-tailed Fisher’s exact test was performed to analyze the differences of the potential risk of PGVs between the left and right sides. The average DAVC−PGVs and DO−PGVs differences between the left and right sides were analyzed by T test, respectively. The DO−AVC differences among different INTAs were analyzed by one-way analysis of variance (ANOVA). P values (< 0.05) were considered statistically significant.

Results

A total of 110 consecutive patients with LDH (mean age: 61.43 ± 7.56 yrs) were included in the present study. No significant difference of age between male and female was found (P > 0.05). According to the Grade III, Grade II, Grade I, and N, the potential risk of PGVs at L1-S1 were shown in Table 1; Fig. 3. At L1-L2 with INTA5°, 10°, 15°, there were significant differences between the left and right sides (P < 0.01). Left side of L1, the incidence of Grade III was lowest at 5° (25.5%), and the highest was at 10° (55.5%). Right side of L1, N has the highest incidence at 5° (100%). Left side of L2, the Grade III was lowest at 5° (9.1%), and the highest was at 10° (20.0%). Right side of L2, the Grade III was lowest at 5° (0.9%), and the highest was at 15° (9.1%).At the L3-L4 with INTA 5°, 10°, there were significant differences between left and right side(P < 0.01), but the constituent ratios were not significantly different at 15° (P > 0.05). At the L5 with INTA 5°, 10°, 15°, obvious differences between left and right were found(P < 0.01). At the S1 with INTA 5°, 10°, there were significant differences between left and right, but the constituent ratios were not significantly different at 0°, 15° (P > 0.05).

Table 1 The type of DAVC−PGV with different INTA and the difference of DAVC−PGV (mm) between left side and right side at L1-S1
Fig. 3
figure 3

Ratio of potential damage risk to anterior vertebral vessels caused by left and right pedicle screws with different INTA (L1: figure A, L2: figure B, L3: figure C, L4: figure D, L5: figure E, S1: figure F). Grade III, II, I and N represent respectively: DAVC−PGVs ≤ 3 mm, 3 mm < DAVC−PGVs ≤ 5 mm, DAVC−PGVs > 5 mm, and no touching of blood vessels. DAVC−PGV: the distance between AVC and PGV, AVC: anterior vertebral cortex, PGV: prevertebral great vessels, INTA: introversion angles, L: lumbar, S: sacral

The DO-AVCs and DO-PGVs were shown in Table 2; Fig. 4. The DO-AVCs were significant differences at different INTAs of L1-S1 (P < 0.01). When INTA was 5°, the maximum distance was measured at L2 and L3 (52.47 mm, 52.31 mm), the minimum distance was measured at S1 (41.03 mm). At L1-L4, the INTA increased 5°, the screw length increased 3 mm. At L5-S1, the INTA increased 5°, the screw length increased 4 mm. At L1 DO-PGVs, there were significant difference between the left side and right side (P < 0.01), and the minimum distance of left was 56.21 mm. At L2, there were no marked difference of DO-PGVs between left side and right side (P > 0.05), and when INTA was 5°, the average distance was 60 mm (range, 48–73 mm). At L3, when INTA was 5° and 10°, there were no significant difference of DO-PGVs between the left and right side (P > 0.05), the distance of left side was 62.50 mm, the right side was 58.37 mm. However, the left and right of DO-PGVs were significant difference when INTA was 15° (P < 0.05). For L4 DO-PGVs, there were significant differences between the left and right side when INTA was 5° and 10° (P < 0.05), but no significant difference at 15° (P > 0.05).No significant difference of L5 DO-PGVs between the left and right side was found (P > 0.05), the distance of left was 50.84 mm when INTA was 5°, and right side was 56.31 mm when INTA was 10°. As for S1 DO-PGVs, there were no marked difference between the left and right side (P > 0.05), the distance of left side and right side was 44.26 mm, 44.01 mm when INTA was 5°, respectively; and 53.57 mm, 53.76 mm when INTA was 15°, respectively.

Table 2 The average DO−AVC (mm) with different INTAs and the difference of DO−PGV (mm) between left side and right side at L1-S1
Fig. 4
figure 4

The maximum length of pedicle screw insertion (DO−AVC) and the distance between the entry point of the left pedicle screw and the anterior vertebral vessels (DO−PGVs). D’O−PGVs represent the distance between the entry point of the right pedicle screw and the anterior vertebral artery. Figure A-E were The length variation diagrams of DO−AVC, DO−PGVs and D’O−PGVs with INTA 5°, 10° and 15° at L1-L5, respectively; F was the length variation diagram of DO−AVC, DO−PGVs and D’O−PGVs with INTA 0°, 5°, 10° and 15° at S1. AVC: anterior vertebral cortex, PGV: prevertebral great vessels, INTA: introversion angles, L: lumbar, S: sacral

The average DAVC−PGVs with different INTAs of L1-S1 were shown in Table 3. At L1-L4, there were significant differences of DAVC−PGVs between the left side and right side when INTA was 5, 10, 15° (P < 0.01) except 10° at L3. As for L5 DAVC−PGVs, notable differences of between left and right sides were found when INTA was both 5° and 10° (P < 0.01), but no significant difference when INTA was 15° (P > 0.05). At S1, there were obvious differences of DAVC−PGVs between the left side and right side when INTA was 0°, 5° and 10° (P < 0.01), however, no significant difference was occurrence when INTA was 15° (P > 0.05).

Table 3 The average DAVC−PGV (mm) with different INTA at L1-S1

Discussion

Vascular injury during spine surgery is a devastating complication, the incidence depends on the anatomical region, surgical approach, and surgical technique [2, 3, 7, 11, 12]. Thus, the safety and accuracy of pedicle screws are of great concern to surgeons. Some studies pointed out that the robot-assisted system can not only visualize the probing hole but also the position of screw in real time, which could improve the safety of the operation [13, 14]. Also, some authors found the robot-assisted system can reduce the perforation rate [13, 15]. However, a meta-analysis including 15 eligible RCTs concluded no significant difference among the Orthbot-assisted technique, the Renaissance-assisted technique, the conventional freehand technique, and the Spine Assist-assisted technique in accuracy of pedicle screws was found [16]. Also, a systematic review and meta-analysis showed there was no significant difference of accuracy of pedicle screws with Robotic surgery and freehand/conventional surgery [7]. Therefore, there is no consensus on whether the new navigation system can improve the safety performance of pedicle screws. In addition, many medical centers do not have computer-assisted equipment and those are not widely used.

At present, the range of DAVC−PGVs and DO−PGVs with different INTAs in thoracic spine have been analyzed in some studies [8, 17, 18]. However, the relationship of DO−PGVs and different INTAs at lumbosacral region has not been quantified at length. A study including a total of 9179 pedicle screws in the thoracic or lumbosacral spine found 210 (2.3%) malpositioned screws with freehand pedicle screw placement, eleven screws (0.12%) were significantly malpositioned and required a second operation for screw revision [19]. Foxx et al. retrospectively analyzed 680 pedicle screws distributing thoracolumbar and lumbosacral fusion, and found 33 of those were in contact with the great vessels, including 4 cases of the aorta, 7 cases of the iliac artery, and 22 cases of the iliac vein. No patients developed any symptoms or sequelae due to contact between the great vessels and pedicle screws during the 44-month follow-up period [20]. Early study has shown that screw misplacement was 6.5%, Screw breakage occurred in 12.4% of the patients [2]. With the popularization and proficiency of pedicle screw technology, the accuracy of screw insertion is also constantly improving. Based on anatomical features, if the screw penetrated unfortunately cortex of vertebrae with the tip to the appropriate length, the structures in front of the vertebral body such as large blood vessels, would not be in danger. The intraoperative INTA is closely related to the length of pedicle screws and the rupture of pedicle wall. Excessive INTA of screws can easily enter the spinal canal and damage nerves; and the INTA is too small, the screw may be located outside the pedicle, resulting in insufficient screw holding force and injury of blood vessels and nerves. From the present results, the recommended INTA was 5° at L1-L2, left 0–10° and right 0–15° at L3, left was 10° and right 0–5° at L4, left 15° and right 0–5° at L5, 0–15° at S1.

Studies found bicortical pedicle screw especially for patients with osteoporosis, can increase in depth of insertion of the pedicle screw resulting in higher pullout force and energy, and the stress was dispersed between the two cortical bone, so that the fixation strength of cortical bone was significantly higher than the cancellous bone [18, 21]. Some authors suggested the bicortical pedicle screw should penetrate with the tip no more than 1 thread beyond the cortical surface [22], and another authors proposed that the screw tip should penetrate no more than 2 mm through the anterior cortex of the vertebral body [23]. Some studies pointed out the perforation range was about 2–4 mm, so the vascular that the distance of DAVC−PGVs less than 3 mm are great injured risk [24, 25]. Therefore, considering the PGVs might be irritated due to their pulsating, the appropriate safe distance between the bicortical pedicle screw and the PGV was approximately 5 mm. Under normal conditions, with mastering screw insertion technology and the help of X-ray fluoroscopy assistance, it was unlikely for the bicortical pedicle screw to exceed 5 mm in front of the vertebral body. Therefore, when the DAVC−PGV was greater than 5 mm, the bicortical pedicle screw was not likely to damage the PGVs. However, if the DAVC−PGV was less than 5 mm, the bicortical pedicle screw had a higher risk of injuring the PGVs due to the narrow a vascular space in front of the vertebral body. The smaller the DAVC−PGV is, the higher the risk is to injury the PGV. In the present study, when INTA was 5°, the risk of vertebral vascular injury was greater than 10% except for the right side of L1, the left and right sides of L2-L3, and the left side of L4, this finding similar to other studies [8, 9]. In addition, our results found at L5-S1, the risk of vascular injury was highest, the average distance of DAVC−PGVs less than 4 mm, indicating that once the pedicle screw penetrates the prevertebral cortex, the prevertebral blood vessels will inevitably be damaged. At L5-S1, the present results showed the DO−AVC was 40 mm to 50 mm, meaning that our choice of screw length is limited. Due to the limitation of anatomical structure at S1, the theoretical optimal INTAs may not be realized, only 35 mm pedicle screw can be selected when INTA was 0°, and 40 mm pedicle screw can be selected when INTA was 5 °, but shorter screw depth could not achieve adequate stability in patients with osteoporosis. The present result also indicated when the INTAs increased by 5°, the screw depth increased by 3 mm to 4 mm, therefore, we recommend using 3 mm increments in screw length to reduce vascular damage and increase stability.

Major vascular injury is a known complication of spinal surgery. according to our study result, the possibility that pedicle screw contacted with arteries was more than the possibility contacted with veins at L4, right pedicle screw was more likely to contact with veins than arteries at L5, left pedicle screw was more likely to contact with veins (e.g. left common iliac vein) than arteries, right pedicle screw was more likely to contact with arteries (e.g. right internal iliac artery) than veins (e.g. right common iliac vein) at S1. In summary, we should focus on arterial damage at L4, vein damage at the right of L5 and left common iliac vein and right internal iliac artery at S1.

Our study has certain limitations. First, the data have unavoidable measurement errors. Second, all CT images were taken in the supine position, and the traditional surgical position is the prone position. However, Riccio et al [26] found that the inferior vena cava and the abdominal aorta in the lumbar region is steady whatever in the prone and supine positions. On the other hand, Li Zhao et al [18] found that lumbar lordosis did not significantly affect the distance between the lumbar spine and PGVs at any level. Finally, because screw implantation is not only at the axial plane of the vertebral body but also has a difference in screw length depending on the head and tail inclination in the sagittal plane, further study should be carried out to assess the situation.

Conclusions

According to the analyzed of different parameters, L1-S1 vascular damage potential risks were different; the risk of L5-S1 was the highest. Therefore, the screw length was limited and the anterior vertebral cortex should be avoided penetrated at L5-S1. Meanwhile, we recommend using 3 mm increments in screw length to reduce vascular damage. And left common iliac vein and the right internal iliac artery damage should be paid more attention when pedicle screw is placed at S1.

Data availability

All data generated or analyzed during this study are included in this published article.

References

  1. Kayaci S, Cakir T, Dolgun M, Cakir E, Bozok S, Temiz C, Caglar YS. Aortic Injury by thoracic pedicle screw. When is aortic repair required? Literature review and three new cases. World Neurosurg. 2019;128:216–24.

    Article  PubMed  Google Scholar 

  2. Jutte PC, Castelein RM. Complications of pedicle screws in lumbar and lumbosacral fusions in 105 consecutive primary operations. Eur Spine J. 2002;11(6):594–8.

    Article  CAS  PubMed  Google Scholar 

  3. Loh SA, Maldonado TS, Rockman CB, Lamparello PJ, Adelman MA, Kalhorn SP, Frempong-Boadu A, Veith FJ, Cayne NS. Endovascular solutions to arterial injury due to posterior spine surgery. J Vasc Surg. 2012;55(5):1477–81.

    Article  PubMed  Google Scholar 

  4. Hansen-Algenstaedt N, Chiu CK, Chan CY, Lee CK, Schaefer C, Kwan MK. Accuracy and safety of fluoroscopic guided percutaneous pedicle screws in thoracic and lumbosacral spine: a review of 2000 screws. Spine (Phila Pa 1976). 2015;40(17):E954–63.

    Article  PubMed  Google Scholar 

  5. Gao F, Zhao X, Sun W, Abhinav P, Li Z. Course of major paravertebral vessels and the positional relationship to the vertebral bodies in healthy Chinese subjects: a CT-based study. Chin Med J (Engl). 2014;127(22):3887–93.

    Article  PubMed  Google Scholar 

  6. Cordemans V, Kaminski L, Banse X, Francq BG, Cartiaux O. Accuracy of a new intraoperative cone beam CT imaging technique (Artis Zeego II) compared to postoperative CT scan for assessment of pedicle screws placement and breaches detection. Eur Spine J. 2017;26(11):2906–16.

    Article  PubMed  Google Scholar 

  7. Luengo-Matos S, Sanchez-Gomez LM, Hijas-Gomez AI, Garcia-Carpintero EE, Ballesteros-Masso R, Polo-Desantos M. Efficacy and safety of robotic spine surgery: systematic review and meta-analysis. J Orthop Traumatol. 2022;23(1):49.

    Article  PubMed  PubMed Central  Google Scholar 

  8. Xu C, Hou Q, Chu Y, Huang X, Yang W, Ma J, Wang Z. How to improve the safety of bicortical pedicle screw insertion in the thoracolumbar vertebrae: analysis base on three-dimensional CT reconstruction of patients in the prone position. BMC Musculoskelet Disord. 2020;21(1):444.

    Article  PubMed  PubMed Central  Google Scholar 

  9. Liu L, Wang H, Wang J, Wang Q, Cheng S, Li Y, Jin W, Wang Z, Zhou Q. The methods for inserting lumbar bicortical pedicle screws from the anatomical perspective of the prevertebral great vessels. BMC Musculoskelet Disord. 2019;20(1):380.

    Article  PubMed  PubMed Central  Google Scholar 

  10. Takeshita K, Maruyama T, Ono T, Ogihara S, Chikuda H, Shoda N, Nakao Y, Matsudaira K, Seichi A, Nakamura K. New parameters to represent the position of the aorta relative to the spine for pedicle screw placement. Eur Spine J. 2010;19(5):815–20.

    Article  PubMed  PubMed Central  Google Scholar 

  11. Peng JC, Guo HZ, Zhan CG, Huang HS, Ma YH, Zhang SC, Xu YR, Mo GY, Tang YC. Comparison of pedicle screw fixation with or without cement augmentation for treating single-segment isthmic spondylolisthesis in the osteoporotic spine. Sci Rep. 2023;13(1):827.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  12. Yang H, Liu Z, Guan L, Liu Y, Liu T, Hai Y. Is the risk of Aorta Injury or Impingement higher during correction surgery in patients with severe and rigid scoliosis? World Neurosurg. 2020;139:e626–34.

    Article  PubMed  Google Scholar 

  13. Matur AV, Palmisciano P, Duah HO, Chilakapati SS, Cheng JS, Adogwa O. Robotic and navigated pedicle screws are safer and more accurate than fluoroscopic freehand screws: a systematic review and meta-analysis. Spine J. 2023;23(2):197–208.

    Article  PubMed  Google Scholar 

  14. Zhang JN, Fan Y, He X, Liu TJ, Hao DJ. Comparison of robot-assisted and freehand pedicle screw placement for lumbar revision surgery. Int Orthop. 2021;45(6):1531–8.

    Article  PubMed  Google Scholar 

  15. Molliqaj G, Schatlo B, Alaid A, Solomiichuk V, Rohde V, Schaller K, Tessitore E. Accuracy of robot-guided versus freehand fluoroscopy-assisted pedicle screw insertion in thoracolumbar spinal surgery. Neurosurg Focus. 2017;42(5):E14.

    Article  PubMed  Google Scholar 

  16. Xie LZ, Wang QL, Zhang Q, He D, Tian W. Accuracies of various types of spinal robot in robot-assisted pedicle screw insertion: a bayesian network meta-analysis. J Orthop Surg Res. 2023;18(1):243.

    Article  PubMed  PubMed Central  Google Scholar 

  17. Dzierżanowski J, Skotarczyk M, Baczkowska-Waliszewska Z, Krakowiak M, Radkowski M, Łuczkiewicz P, Czapiewski P, Szmuda T, Słoniewski P, Szurowska E, Winklewski PJ, Demkow U, Szarmach A. Morphometric analysis of the lumbar vertebrae concerning the optimal screw selection for Transpedicular stabilization. Adv Exp Med Biol. 2019;1133:83–96.

    Article  PubMed  Google Scholar 

  18. Zhao L, Wan C, Han S, Li B, Zheng S. The study of distance changes between lumbar bi-cortical pedicle screws and anterior large vessels in patients with lumbar spondylolisthesis. BMC Musculoskelet Disord. 2021;22(1):920.

    Article  PubMed  PubMed Central  Google Scholar 

  19. Alomari S, Lubelski D, Lehner K, Tang A, Wolinsky JP, Theodore N, Sciubba DM, Larry LS, Belzberg A, Weingart J, et al. Safety and Accuracy of Freehand Pedicle Screw Placement and the role of intraoperative O-Arm: a single-Institution experience. Spine (Phila Pa 1976). 2023;48(3):180–8.

    Article  PubMed  Google Scholar 

  20. Foxx KC, Kwak RC, Latzman JM, Samadani U. A retrospective analysis of pedicle screws in contact with the great vessels. J Neurosurg Spine. 2010;13(3):403–6.

    Article  PubMed  Google Scholar 

  21. Spirig JM, Winkler E, Cornaz F, Fasser MR, Betz M, Snedeker JG, Widmer J, Farshad M. Biomechanical performance of bicortical versus pericortical bone trajectory (CBT) pedicle screws. Eur Spine J. 2021;30(8):2292–300.

    Article  PubMed  Google Scholar 

  22. Bezer M, Ketenci IE, Saygi B, Kiyak G. Bicortical versus unicortical pedicle screws in direct vertebral rotation: an in vitro experimental study. J Spinal Disord Tech. 2012;25(6):E178–82.

    Article  PubMed  Google Scholar 

  23. Karami KJ, Buckenmeyer LE, Kiapour AM, Kelkar PS, Goel VK, Demetropoulos CK, Soo TM. Biomechanical evaluation of the pedicle screw insertion depth effect on screw stability under cyclic loading and subsequent pullout. J Spinal Disord Tech. 2015;28(3):E133–9.

    Article  PubMed  Google Scholar 

  24. Dunn C, Faloon M, Milman E, Pourtaheri S, Sinah K, Hwang K, Emami A. Accuracy and safety of Percutaneous Lumbosacral Pedicle Screw Placement using dual-Planar Intraoperative Fluoroscopy. Asian Spine J. 2018;12(2):238–45.

    Article  PubMed  PubMed Central  Google Scholar 

  25. Kim MC, Chung HT, Cho JL, Kim DJ, Chung NS. Factors affecting the accurate placement of percutaneous pedicle screws during minimally invasive transforaminal lumbar interbody fusion. Eur Spine J. 2011;20(10):1635–43.

    Article  PubMed  PubMed Central  Google Scholar 

  26. Riccio AR, Bishop A, Carl AL. Great vessel excursion: Prone Versus Supine position. Int J Spine Surg. 2019;13(2):158–61.

    Article  PubMed  PubMed Central  Google Scholar 

Download references

Acknowledgements

Not Applicable.

Funding

The study was supported by National Natural Science Foundation of China (81702198), National Natural Science Foundation of Hubei province (2023AFB1006) and Hubei Provincial Health Commission Young Talent Program (WJ2023Q020).

Author information

Authors and Affiliations

Authors

Contributions

Author contributions to the study and manuscript preparation include the following. Conception and design: WF W. clinical assessment: J L, JY Y, Y C. Data analysis: JY Y, Y C. Drafting the article: JY Y, Y C. Critically revising the article: WF W. Reviewed final version of the manuscript and approved it for submission: all authors. Study supervision: WF W.

Corresponding author

Correspondence to Weifei Wu.

Ethics declarations

Ethics approval and consent to participate

Before the study was carried out, the Ethics Committee of the People’s Hospital of China Three Gorges University had approved the research plan. All participators signed informed consent of permitting their clinical data to be used for the study. All study methods were conducted in accordance with the Three Gorges University guidelines and regulations.

Consent for publication

Not applicable.

Competing interests

The authors declare no competing interests.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Junyi Yang and Ying Chen were co-first author.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Chen, Y., Yang, J., Liang, J. et al. The optimal introversion angle and length of pedicle screw to avoid L1-S1 vascular damage. BMC Surg 24, 194 (2024). https://doiorg.publicaciones.saludcastillayleon.es/10.1186/s12893-024-02483-3

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doiorg.publicaciones.saludcastillayleon.es/10.1186/s12893-024-02483-3

Keywords