Purpose
Achieving and maintaining an optimal reduction in partially or fully displaced intra-articular fractures, specifically Type C distal radius fractures, can present challenges. This study aims to retrospectively evaluate and summarize a method utilizing multi-directional temporary Kapandji technique in combination with the volar locking plate fixation for these fractures.
Method
The study involved 15 patients diagnosed with Type C distal radius fractures who underwent surgery between January 2024 and April 2024. The procedure incorporated a multi-directional temporary Kapandji technique, followed by stable osteosynthesis using a volar locking plate system. The functional outcomes were assessed after 4 (2–6) months of follow-up using the modified Mayo wrist scoring system (MMWS). The MMWS is a rating system used to evaluate wrist function and pain, including pain, motion, grip strength.
Results
All the patients incision healed within 2 weeks. All the fractures had uneventful union within 8–12 weeks. Based on the modified Mayo wrist scoring (MMWS) system, most patients showed good to excellent functional recovery.
Conclusion
This reduction method proved to be both simple and replicable, enabling satisfactory alignment with minimal force. The volar locking plate system provided rigid and stable fixation.
Introduction
Distal radius fractures are frequently encountered in the clinical settings, with 41-50% affecting the articular surfaces of the distal radius [1]. While CT scanning offers a superior means of fracture evaluation, both conservative and surgical treatments are available. Recent advances in the implants and surgical methods have made surgery a more viable option, often yielding improved outcomes. The volar locking plate is increasingly favored due to its straightforward approach and the associated high rate of functional recovery [2,3,4,5]. Achieving proper fracture reduction is crucial when using the volar plate for osteosynthesis in dorsally and radially displaced Type C fractures [6,7,8,9]. Kapandji introduced a technique that employs the Kirschner wires (K-wires) to lever the displaced fragment of a distal radius fracture into alignment [10]. This method, which facilitates both reduction and fixation, is particularly useful for treating irreducible, comminuted fractures. By applying volar-directed force with the Kapandji technique, dorsally displaced fragments can be effectively reduced, especially to restore anatomic volar tilt. We propose a multi-directional temporary Kapandji technique combined with volar locking plate fixation to aid in the reduction of Type C distal radius fractures, positioning the bone centrally with the K-wires and plate on either side. This study aims to summarize a method utilizing multi-directional temporary Kapandji technique in combination with the volar locking plate fixation for these fractures.
Patients and methods
Fifteen patients with Type C distal radius fractures were treated surgically between January and April 2024. The mean age of the patients was 57 years (range 45–70), 5 men and 10 women. The mechanism of injury was fall injury. The procedure incorporated the multi-directional temporary Kapandji technique, followed by stable osteosynthesis using a locking plate system. Initial management involved manual fracture reduction and plaster external fixation to alleviate pain. Surgical intervention was performed within 5–7 days post-injury. All fractures were classified using the AO system and evaluated through standard wrist radiographs and CT scans. Informed consent was obtained from each patient.
Surgical techniques
Approach
The volar Henry approach, which lies between the radial artery and the flexor carpi radialis tendon, was used for most fractures. A longitudinal skin incision aligned with the flexor carpi radialis tendon was made, and the fracture site was exposed by subperiosteal elevation of the pronator quadratus.
Multi-direction temporary Kapandji technique
Fracture reduction was initiated with traction and counter-traction, followed by marking the insertion points for the K-wires. Temporary stabilization was achieved using 1.5-mm K-wires. The first K-wire was inserted percutaneously along the lateral margin of the radius, reducing the radial styloid fragment and restoring the distal radial height (Fig. 1a). The second K-wire was placed at the apex of the radial styloid and passed through the opposite cortical bone to secure the radial styloid (Fig. 1b). Two additional K-wires were introduced dorsally to restore volar tilt by leveraging the dorsal cortex; once corrected, the K-wire was advanced to the volar cortex (Fig. 1c-d). An additional K-wire was used to stabilize the ulnar fragment (Fig. 1e). In some cases, more than two K-wires were applied. Fluoroscopic imaging confirmed correct K-wire placement and successful fracture reduction.
Volar locking plate fixation
The volar locking plate was positioned in the appropriate location, and temporary stabilization was achieved using 1.0-mm K-wires to hold the plate onto the bone. Initially, a cortical screw was inserted into the oblong hole to secure the plate. Once the cortical screw was tightened, the plate was adjusted to the correct level, verified using lateral fluoroscopic views. Locking screws were then inserted to provide firm fixation of the fragments.
Functional evaluation criteria
The clinical outcomes were evaluated using the modified Mayo wrist scoring (MMWS) system including pain, motion, grip strength. The ability to return to regular employment or activities after 2 weeks [11]. Good to excellent outcomes could be achieved in most cases. An excellent result was defined as 90 to 100 points, good was 80 to 89, fair was 65 to 79 points, and poor was < 65 points.
Results
All the patients were reviewed. No major medical complications, no infection, delayed union, or nonunion, no further fracture displacement or extensor tendon ruptures was recorded. All the patients incision healed within 2 weeks. All the fractures had uneventful union within 8–12 weeks. The functional outcomes were assessed average follow-up of 4 (2–6) months. According to the MMWS system, the functional assessment revealed good to excellent results in most cases (Table 1).
Cases presentations
Case 1
A 64-year-old female presented with left wrist pain and swelling because of falling. A thorough examination revealed a distal radius fracture. After the fracture of the patient, the first is manual reduction, and then plaster external fixation to reduce the pain. Giving cold compress, other treatments were relieving swelling and pain. Preoperative wrist CT examination was performed to evaluate the fracture (Fig. 2a). The reduction of the fracture was performed using the multi-direction temporary Kapandji technique, and the volar locking plate can be placed in the appropriate position (Fig. 2b-c). Wrist CT was reviewed again after surgery to evaluate fracture reduction and the position of plates and screw (Fig. 2d).
Case 2
A 56-year-old male was hospitalized with distal radius fracture (Fig. 3a). Preoperative wrist CT examination was performed to evaluate the fracture (Fig. 3b). The reduction of the fracture was performed using the multi-direction temporary Kapandji technique, and the volar locking plate can be placed in the appropriate position (Fig. 3c). Wrist CT was reviewed again after surgery to evaluate fracture reduction and the position of plates and screw (Fig. 3d).
Discussion
There are multiple treatment options for the distal radius fractures, including open reduction with plate fixation, external fixators, and conservative approaches [3]. Achieving a proper reduction is crucial for ensuring good functional outcomes, and we support the view that better fracture reduction plays a pivotal role in predicting the overall functionality post-treatment [12].
In particular, open reduction combined with volar locking plate fixation has emerged as a leading approach, especially for treating Type C distal radius fractures [13]. Several studies have demonstrated positive results, particularly when temporary Kapandji is used alongside external fixation [12]. Kapandji originally described a method using K-wires to fix distal radius fractures [14, 15]. While K-wire fixation remains a widely used technique, it has faced criticism for its instability and the challenges in maintaining reduction [16,17,18].
In this study, we employed a combination of multi-directional temporary Kapandji and volar locking plate fixation to treat Type C distal radius fractures. Initially, Kapandji K-wires were utilized to reduce dorsally displaced fractures, applying volar-directed force to restore volar tilt. Next, bilateral Kapandji K-wires were inserted to reduce displaced fragments and apply ulnar-directed force, restoring radial height and inclination. Finally, an anatomical plate was used to buttress and reposition the distal fragment, completing the osteosynthesis.
Patient outcomes are largely determined by the quality of the reduction, including factors like radial height, radial inclination, ulnar variance, and volar/dorsal tilt [19]. However, based on our experiences, postoperative functional exercise is of greater importance. Once patients can tolerate incision pain, functional exercises begin under medical guidance, starting with finger flexion and extension and gradually progressing to wrist movement. The selection of the timing for rehabilitation is critical. Most researchers agree that initiating functional exercises earlier and minimizing prolonged postoperative joint immobilization can lead to better recovery of wrist joint function [20]. Therefore, we recommend starting finger functional exercises within 24 h after surgery and encouraging light functional activities using the injured limb [21]. This rehabilitation protocol helped avoid complications such as finger or wrist stiffness.
The advantages of the technique offer simplicity, reproducibility, and eliminates the need for dorsal exposure by only requiring a volar approach; no further fracture displacement was found after volar locking plate fixation. The patients were able to encourage the postoperative rehabilitation protocol. But our study possessed some limitations such as the follow-up time was short, small number of patients and was not compared with other techniques.
The multi-directional temporary Kapandji technique aids surgeons in achieving optimal reduction prior to placing the volar plate when treating displaced Type C distal radius fractures.
Conclusions
The use of multi-directional temporary Kapandji in combination with volar locking plate fixation for Type C distal radius fractures is both feasible and effective. It is a recommended approach for treating Type C distal radius fractures.
Data availability
The data presented in this study are available on request from the corresponding author.
Abbreviations
- MMWS:
-
Modified mayo wrist score
- CI:
-
Indicates confidence interval
References
Yan B, Chen Y, Yin W. Influence of distal radius fractures involving the intermediate column on forearm rotation. J Orthop Surg Res. 2019;14(1):111.
Woolnough T, Axelrod D, Bozzo A, et al. What Is the Relative Effectiveness of the Various Surgical Treatment Options for Distal Radius Fractures? A Systematic Review and Network Meta-analysis of Randomized Controlled Trials. Clin Orthop Relat Res. 2021;479(2):348–62.
Akdemir M, Kiliç AĪ, Kurt C, Çapkin S. Open Reduction and Plate Fixation, External Fixator, and Conservative Treatment for Intra-articular Distal Radius Fractures. Cureus. 2024;16(1):e52014.
Roh YH, Lee BK, Baek JR, Noh JH, Gong HS, Baek GH. A randomized comparison of volar plate and external fixation for intra-articular distal radius fractures. J Hand Surg Am. 2015;40(1):34–41.
Gui XY, Cheng ZH, Shi HF, et al. Single volar locking plating for the intra- and extra-articular distal radius fractures with dorsal metaphyseal comminution. J Orthop Surg Res. 2022;17(1):81.
Earp BE, Foster B, Blazar PE. The use of a single volar locking plate for AO C3-type distal radius fractures. Hand (N Y). 2015;10(4):649–53.
Lundqvist E, Fischer P, Wretenberg P, Pettersson K, Lopez Personat A, Sagerfors M. Volar Locking Plate Compared with Combined Plating of AO Type C Distal Radius Fractures: A Randomized Controlled Study of 150 Cases. J Hand Surg Am. 2022;47(9):813–22.
Zhang L, Wang M, Liu Z, et al. Open Reduction and Internal Fixation by Volar Locking Plates and the Poking Reduction Technique in Distal Radius Fractures with Displaced Dorsal Ulnar Fragments: A Retrospective Study. Orthop Surg. 2022;14(10):2489–98.
Zhou Y, Zhu Y, Zhang X, Tian D, Zhang B. Comparison of radiographic and functional results of die-punch fracture of distal radius between volar locking plating (VLP) and external fixation (EF). J Orthop Surg Res. 2019;14(1):373.
Kapandji A. L’ostéosynthèse par double embrochage intra-focal. Traitement fonctionnel des fractures non articulaires de l’estrémité inférieure du radius [Internal fixation by double intrafocal plate. Functional treatment of non articular fractures of the lower end of the radius (author’s transl)]. Ann Chir. 1976;30(11–12):903–8.
Jia Z, Wang S, Jiang W, et al. The treatment of complex intra-articular distal radius fractures with turning radius and distal volaris radius plate fixation. Eur J Med Res. 2020;25(1):66.
Jirangkul P, Jitprapaikulsarn S, Songpatanaslip T. Outcomes Following Temporary Kapandji Pinning Technique and Distal Radial LCP Fixation for Intra-Articular Fractures of the Displaced Distal Radius. Tech Hand Up Extrem Surg. 2019;23(1):38–43.
Chen AC, Cheng CY, Weng CJ, Chou YC. Intramedullary nailing and plating osteosynthesis in the correction of post-traumatic deformity in late-diagnosed distal radius fractures: a retrospective comparison study. BMC Musculoskelet Disord. 2019;20(1):236.
Jayaram M, Wood SM, Kane RL, Yang LY, Chung KC. Association of Open Reduction and Internal Fixation With Volar Locking Plate for Distal Radius Fractures With Patient-Reported Outcomes in Older Adults: A Network Meta-analysis. JAMA Netw Open. 2023;6(6):e2318715.
Handoll HH, Huntley JS, Madhok R. External fixation versus conservative treatment for distal radial fractures in adults. Cochrane Database Syst Rev. 2007;(3):CD006194.
Vidyadharan A. A Novel Method of Closed Reduction and Percutaneous Pinning With Six K-wires for Intra-articular Fractures of the Distal Radius. J Am Acad Orthop Surg Glob Res Rev. 2020;4(6):e1900114.
Del Piñal F, Jupiter JB, Rozental TD, Arora R, Nakamura T, Bain GI. Distal radius fractures. J Hand Surg Eur Vol. 2022;47(1):12–23.
Tajeddin F, Esmaeilnejadganji SM, Baghiani Moghaddam B, Kamali Ahangar S, Bahrami Feridoni M. Percutaneous pinning versus pin-in-plaster for treatment of distal radius fractures. Casp J Intern Med. 2019;10(3):309–13.
Combined Randomised and Observational Study of Surgery for Fractures in the Distal Radius in the Elderly (CROSSFIRE) Study Group, Lawson A, Naylor JM, et al. Surgical Plating vs Closed Reduction for Fractures in the Distal Radius in Older Patients: A Randomized Clinical Trial. JAMA Surg. 2021;156(3):229–37.
Hou Jiguang Z, Shenghua W, Qi, et al. Effect of Early Rehabilitation on Wrist Joint Function Recovery after Distal Radius Fracture Surgery [J]. Chin J Bone Joint Injury. 2017;32(1):98–9.
Trauma Orthopedics Group of Orthopedics Branch of Chinese Medical Association, External Fixation and Limb Reconstruction Group of Orthopedics Branch of Chinese Medical Association. Clinical Guidelines for the Diagnosis and Treatment of Adult Distal Radius Fractures in China [J]. Chin J Orthop Trauma. 2023;25(1):6–13.
Acknowledgements
We thank the reviewers and editors for their helpful comments on this article.
Funding
This work was supported by the Specialty construction foundation: The clinical specialty construction foundation of Shandong Province (2020), Grant umber SLCZDZK-0303.
Ethics declarations
Ethics approval and consent to participate
This study was approved by the Ethics Committee of Binzhou Medical University Hospital (KYLL-216) and conducted in accordance with the Declaration of Helsinki (as revised in 2013). Written informed consent was got from each included patient.
Informed consent
Informed consent was obtained from all participants for using their imaging data and questionnaire scores.
Consent for publication
Written informed consent to publish the clinical details and images of the patient was obtained.
Competing interests
The authors declare no competing interests.
Additional information
Publisher’s note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License, which permits any non-commercial use, sharing, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if you modified the licensed material. You do not have permission under this licence to share adapted material derived from this article or parts of it. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by-nc-nd/4.0/.
About this article
Cite this article
Zhao, W., Song, Kx., Liu, Yt. et al. Clinical application of multi-direction temporary Kapandji technique and volar locking plate fixation for type C distal radius fractures. BMC Surg 24, 404 (2024). https://doiorg.publicaciones.saludcastillayleon.es/10.1186/s12893-024-02725-4
Received:
Accepted:
Published:
DOI: https://doiorg.publicaciones.saludcastillayleon.es/10.1186/s12893-024-02725-4